4.6 DMX 512 connection, master/slave connection
The wires must not come into contact with each other, otherwise
the xtures will not work at all, or will not work properly.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with the xture or one xture
with another.
Occupation of the XLR-connection:
DMX - output DMX-input
XLR mounting-socket: XLR mounting-plug:
Building a serial DMX-chain:
If you are using the standard controllers, you can connect the DMX-output of the controller directly with the DMX-input of the rst xture
in the DMX-chain. If you wish to connect DMX-controllers with other XLR-outputs, you need to use adapter-cables.
Connect the DMX-output of the rst xture in the DMX-chain with the DMX-input of the next xture. Always connect output with the
input of the next xture until all xtures are connected.
Caution: At the last xture, the DMX-cable has to be terminated with a terminator. Solder a 120 Ohm resistor between Signal (–) and
Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last xture.
Building a master/slave-chain:
Connect the DMX-output of the master xture in the data-chain with the DMX-input of the rst slave. Always connect output with the
input of the next slave until all slaves are connected (up to 9 xtures).
Caution:It’s necessary to insert the XLR termination plug (with 120 Ohm) into the input of the master xture and into the output of
the last slave xture in the link in order to ensure proper transmission on the data link.
1 - Ground
2 - Signal (-)
3 - Signal (+)
1 - Ground
2 - Signal (-)
3 - Signal (+)
Master/slave operation