Robe ROBIN Pointe Spezifikationen Seite 24

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 23
24
been fabricated.
Maximum Res. - A maximum temperature of the xture head since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Base Temperature - The menu shows temperature in the xture base (on the display PCB).
Current - A current temperature in the xture base.
Maximum NonRes. - A maximum temperature in the xture base since the xture has
been fabricated.
Maximum Res. - A maximum temperature in the xture base since the counter
was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
Ambient Temperature - The menu shows temperature of the induced air on the fan in the xture base .
Current - A current temperature of the induced air in the xture base.
Maximum NonRes. - A maximum temperature of the induced air in the xture base since
the xture has been fabricated.
Maximum Res. - A maximum temperature of the induced air in the xture base since
since the counter was last reset.
In order to reset this counter to 0, touch the text box next to the item "Maximum Res."
DMX Values - The menu is used to read DMX values of each channel received by the xture.
Wireless State - The menu serves for reading of the wireless operation status (only for Wireless DMX ver-
sion).
Software Version - Select this item to read the software version of the xture modules:
Display System - A display processor on the display board in the xture base
Module M - A pan/Tilt processor
Module G - A Static and rot. gobos + colours processor.
Module P - The prisms and frost processor.
Module O - A focus/zoom/strobe processor
Product IDs - The menu is used to read the MAC Address ,RDM UID and RDM Label.
View Logs - Use this menu to read xture´s data which have been recorded during xture operation. This
colected data allows easier troubleshooting.
Fixture Errors - Use this menu to read xture errors which have occured during xture operation.
There is a list of error folders:
Pan Errors Prism I Errors
Tilt Errors Prism I Rotation Errors
Dimmer Errors Prism 2 Errors
Gobo Carousel Errors Prism 2 Rotation Errors
Colour Errors Lamp is Too Hot
Gobo Errors Overheated
Clean Air Filters Active Lamp Timer
Static Gobo Errors Lamp Errors
Focus Errors Temp. Sensor Errors
Zoom Errors Frost Errors
Error messages regard the lamp driver:
Lamp driver overheated- the lamp driver switched off due to over temperature of driver board.
Lamp driver output short circuit detected - the lamp driver switched off due to a detected short of output
connector or lamp electrodes.
End of lamp life detected - the lamp driver switched off due to end of lamp life time reached,lamp voltage
too high caused by electrode burn back (gap)
Lamp did not ignite - the lamp driver detected that lamp is not on within specied ignition time.
Lamp extinguished during normal operation - the driver switched off due less current through the lamp.
Lamp extinguished during run-up phase - the driver switched off due to too less current within initial
preheat phase of lamp start (approx. initial 2sec)
Fixture States - Recorded following actions: Fixture On, Fixture Off, Lamp On, Lamp Off.
Fixture Position - Recorded installation positions of the xture: